GENKRAFT / Diesel generators / FG WILSON GENKRAFT GK-P3 (33-715 kVA)
Diesel generator set · 50 Hz

FG WILSON GENKRAFT GK-P3 (33-715 kVA)
Diesel Prime & Standby

A single design family, same engine and alternator base, available across the entire power range.

Power range
33 – 715 kVA
· 13 steps
FG WILSON GENKRAFT GK-P3 (33-715 kVA) - Image 1
Configure

Choose power and execution

Configure the generator according to your needs. Choose the required power, execution type and desired options.

Specifications are automatically updated based on your selection

50 Hz
Prime Power (PRP)
30kVA / 24 kW
Standby Power (ESP)33 kVA
Rated current43 A
Technical sheet · marked values change with selection
Voltage / Frequency230/400V / 50 Hz
Dimensions (L×W×H)1900 × 900 × 1350 mm
Operating mass843 kg
Fuel tank100 L
Consumption at 100% load6.1 L/h
ExecutionOpen

Prefer to talk? Call +40 769 081 081

Product description

400 kVA GENKRAFT diesel generator, three-phase 33-715 kVA

Looking for a standby range that covers almost any load, from a building to a factory? A 400 kVA GENKRAFT generator is part of the main diesel generator line, from 33 to 715 kVA, designed for both medium loads and large industrial consumers.

It is one product configurable across the entire range: choose the power, configuration and options. A 400 kVA generator delivers stable three-phase power at 400 V and 50 Hz, with both prime and standby ratings, and starts automatically when the grid fails.

Advantages of a GENKRAFT industrial diesel generator

  • Configurable 33-715 kVA range: choose the right power level, from the smallest to the largest rating in the line, without paying for unused capacity.
  • Prime and standby ratings are stated in accordance with ISO 8528, so you know exactly what a 400 kVA generator delivers in each operating mode.
  • Stable three-phase supply at 230/400 V and 50 Hz, matching the Romanian grid standard and suitable for motors and sensitive equipment.
  • Automatic start on mains failure with an optional ATS panel, so a 400 kVA generator takes over the loads without human intervention.
  • Three configurations: open for a technical room, soundproof enclosed for outdoor installation, and containerized for a fully independent installation.
  • Liquid-cooled diesel engine and brushless alternator with 100% copper windings, components selected for reliable operation and dependable starting.
  • CE marking and conformity documentation, making the 400 kVA generator eligible for projects financed with European funds.
  • Direct-supplier pricing without the markup of an expensive brand: you pay for the technology and components, not the name on the enclosure.

Technical specifications for the 400 kVA generator and the rest of the line

A 400 kVA generator is part of a unified product line: the power rating changes while the platform remains the same. The values below are actual prime and standby ratings. Exact dimensions and weight are confirmed in the technical datasheet for each power step.

Model (kVA)Prime power PRPStandby power ESP
33 kVA30 kVA / 24 kW33 kVA / 26,4 kW
50 kVA45 kVA / 36 kW50 kVA / 40 kW
88 kVA80 kVA / 64 kW88 kVA / 70,4 kW
110 kVA100 kVA / 80 kW110 kVA / 88 kW
200 kVA180 kVA / 144 kW200 kVA / 160 kW
220 kVA200 kVA / 160 kW220 kVA / 176 kW
400 kVA350 kVA / 280 kW400 kVA / 320 kW
450 kVA400 kVA / 320 kW450 kVA / 360 kW
500 kVA450 kVA / 360 kW500 kVA / 400 kW
550 kVA500 kVA / 400 kW550 kVA / 440 kW
605 kVA550 kVA / 440 kW605 kVA / 484 kW
660 kVA600 kVA / 480 kW660 kVA / 528 kW
715 kVA650 kVA / 520 kW715 kVA / 572 kW
Voltage230 / 400 V (three-phase, 4 conductors)
Frequency / speed50 Hz / 1500 rpm
Power factor0,8
Cooling / startingLiquid / 24 V DC electric
ConfigurationsOpen, soundproof canopy, containerized
Standard / markingISO 8528, CE marking

How to choose the right power

Sizing starts with the loads the generator must support: production lines, motors, pumps, ventilation, lifts and IT equipment. Add their power requirements, then include a reserve for motor starting, which briefly demands several times the nominal current.

Do not oversize excessively: a generator operated for long periods at too little load does not work at its optimum point. Send us your load list and we will size the correct rating from the 33-715 kVA range and tell you whether a 400 kVA generator covers the requirement or whether the adjacent rating is more suitable.

Operating mode and autonomy

ISO 8528 defines prime power (PRP), available for an unlimited number of hours per year, and emergency standby power (ESP), available for a limited number of hours without overload. This line is rated for both, so it can operate either as the main source or as backup.

Autonomy depends on tank capacity and load. The integrated tank covers a typical standby duty, while extended operation can use a larger tank or external fuel supply. Diesel consumption at 75% and 100% load is stated in the datasheet for each rating.

Why diesel

For industrial power levels, the diesel engine remains the solution with the best balance of cost, autonomy and reliability. It offers high energy density, controlled fuel consumption under load and durability in intensive operation, unlike petrol generators, which are limited to lower power levels.

Unlike a UPS, which covers only a few minutes, a diesel generator can support the load for hours or days as long as fuel is available. That is why it is the standard backup choice for buildings, industry and critical infrastructure.

Components and construction

The technical platform is common across the entire line: liquid-cooled diesel engine, brushless alternator with 100% copper windings and automatic voltage regulator, digital controller with protections, and a frame with anti-vibration mounts for stable installation.

Components are selected for continuous operation and easy spare-parts support. A generator built on a unified platform is easier to maintain and troubleshoot, regardless of the selected power rating.

Configurations and options

Each 400 kVA generator is supplied in the configuration suited to its installation site: open for a technical room or hall, soundproof enclosed for low-noise outdoor installation, or containerized and ready to position, with external access to the control panel.

Options include an ATS automation panel for automatic mains-generator transfer, an extended fuel tank for greater autonomy, industrial sockets and a remote monitoring system. The three-phase output connects directly to the installation's main distribution board.

Applications and industries for the 400 kVA generator

A 400 kVA generator is used in factories, production halls, commercial buildings and hospitals. When the grid fails, it automatically takes over the loads, from process lines and pumps to lifts, ventilation and IT equipment, without a noticeable interruption to operations.

Because the range extends from 33 to 715 kVA, the same line covers both a small commercial load and a large industrial site. A lower-range industrial diesel generator can supply an office or workshop, while the larger ratings support continuous production and refrigeration systems.

For facilities operating non-stop, a 400 kVA generator forms part of the business-continuity plan. See the full GENKRAFT diesel generator range for other lines and power ratings, or request sizing from the GENKRAFT technical team. The equipment carries CE marking in accordance with the applicable requirements of the Machinery Directive 2006/42/EC.

Whatever the application, a 400 kVA generator delivers the same stable three-phase power, with optional automatic starting and a configuration selected for the installation site. A common technical platform across the 33-715 kVA range means shared parts and predictable service.

Installation, delivery and documentation

As a reseller, we prepare every order to the selected configuration: power, enclosure, voltage and options. Delivery time therefore depends on the configuration and is confirmed in the quotation together with the final price.

At delivery, the equipment comes with CE marking and conformity documentation. On request, we provide the technical datasheet and certifications required for a financing file. Electrical connection and commissioning are performed by an authorised electrician in accordance with the site's electrical design.

How it works

A 400 kVA generator follows a simple sequence from mains failure to restoration:

  1. The mains sensor detects loss of supply or a voltage deviation in the public grid.
  2. The ATS automation panel commands the diesel engine to start and disconnects the mains.
  3. The generator reaches rated speed and the alternator delivers stable three-phase voltage.
  4. Within a few seconds of the outage, the ATS transfers the load to the generator without human intervention.
  5. When mains power returns, the system transfers the loads back and stops the engine after the cool-down period.
  6. The digital controller monitors operating parameters and shuts the set down on protection events, with an alarm log.

Frequently asked questions

What is the difference between prime and standby power for a 400 kVA generator?

Prime power is the continuous rating available for an unlimited number of hours per year; standby is the emergency rating for a limited number of hours, without overload. The 400 kVA generator is rated for both according to ISO 8528, as shown on the datasheet for each power step.

What power range does this line cover?

From 33 to 715 kVA. Choose the rating that matches your loads, from a small building to an industrial site, all within the same product line.

Does it automatically take over the loads during a power outage?

Yes. With an ATS automation panel, an industrial diesel generator starts and transfers the load within seconds of a grid failure, then automatically returns to mains power. The ATS is optional and is specified in the quotation.

What configurations are available?

Open for a technical room, soundproof enclosed for low-noise outdoor use, or containerized for an independent installation. The 400 kVA generator is supplied in the version suited to the location.

What maintenance does it require?

Basic maintenance means checking the oil, filters, coolant and battery at the intervals specified in the manual. The digital controller provides early alarm indications, and regular maintenance ensures a long service life.

Can it be monitored remotely?

Yes, optionally. With the monitoring module, generator status, fuel level and alarms can be viewed remotely over the network, which is useful for unattended sites.

How do I order and receive a quote?

Choose the power rating and configuration, then request a quote. We confirm the configuration, price and delivery time. Because each unit is prepared to order, you receive exactly the version suited to your project.

What is the noise level in the enclosed version?

The soundproof enclosure significantly reduces noise compared with the open version, allowing the generator to operate near the building. The exact dB(A) level at 7 metres is stated in the technical datasheet for each power rating.

Do you deliver nationwide?

Yes, we deliver throughout Romania. Electrical connection and commissioning are performed by an authorised electrician in accordance with the site's electrical design, and we provide the required technical documentation.

Is it eligible for projects funded by European funds?

Yes. The equipment comes with CE marking and conformity documentation, so it can be included in co-financed investment projects. On request, we provide the technical datasheet and certifications for the financing file.

Versatile, three-phase and configurable across the 33-715 kVA range, a 400 kVA GENKRAFT generator covers applications from an office building to a factory, at direct-supplier pricing.

Complete specifications

Power (kVA)PRP kWPRP kVAESP kWESP kVAVoltageFrequency
33243026.433230/400V50
5036454050230/400V50
88648070.488230/400V50
1108010088110230/400V50
200144180160200230/400V50
220160200176220230/400V50
400280350320400230/400V50
450320400360450230/400V50
500360450400500230/400V50
550400500440550230/400V50
605440550484605230/400V50
660480600528660230/400V50
715520650572715230/400V50