DOOSAN GENKRAFT GK-D P2
Diesel Prime & Standby
A single design family, same engine and alternator base, available across the entire power range.

Choose power and execution
Configure the generator according to your needs. Choose the required power, execution type and desired options.
Specifications are automatically updated based on your selection
| Voltage / Frequency | 220/380V | 230/400V | 240/415V / 50 Hz |
| Dimensions (L×W×H) | 4250 × 1500 × 2200 mm |
| Operating mass | 5,430 kg |
| Fuel tank | 600 L |
| Consumption at 100% load | 91.8 L/h |
| Execution | Open |
Prefer to talk? Call +40 769 081 081
Product description
625 kVA GENKRAFT diesel generator, three-phase 450-910 kVA
For heavy industry, data centres and critical infrastructure, a 625 kVA generator provides large-scale standby and process power. GENKRAFT covers the high-power segment from 450 to 910 kVA, delivering stable three-phase power where the cost of an outage is extremely high.
It is one configurable product: choose the power rating, enclosure and options. A 625 kVA generator delivers three-phase power at 400 V and 50 Hz, with prime and standby ratings, and automatically takes over major industrial loads within seconds of a grid failure.
Advantages of a high-power GENKRAFT diesel generator
- Configurable 450-910 kVA range: choose the right power level, from the smallest to the largest rating in the line, without paying for unused capacity.
- Prime and standby ratings are stated in accordance with ISO 8528, so you know exactly what a 625 kVA generator delivers in each operating mode.
- Stable three-phase supply at 230/400 V and 50 Hz, matching the Romanian grid standard and suitable for motors and sensitive equipment.
- Automatic start on mains failure with an optional ATS panel, so a 625 kVA generator takes over the loads without human intervention.
- Three configurations: open for a technical room, soundproof enclosed for outdoor installation, and containerized for a fully independent installation.
- Liquid-cooled diesel engine and brushless alternator with 100% copper windings, components selected for reliable operation and dependable starting.
- CE marking and conformity documentation, making the 625 kVA generator eligible for projects financed with European funds.
- Direct-supplier pricing without the markup of an expensive brand: you pay for the technology and components, not the name on the enclosure.
Technical specifications for the 625 kVA generator and the rest of the line
A 625 kVA generator is part of a unified product line: the power rating changes while the platform remains the same. The values below are actual prime and standby ratings. Exact dimensions and weight are confirmed in the technical datasheet for each power step.
| Model (kVA) | Prime power PRP | Standby power ESP |
|---|---|---|
| 450 kVA | 450 kVA / 360 kW | 500 kVA / 400 kW |
| 500 kVA | 500 kVA / 400 kW | 550 kVA / 440 kW |
| 625 kVA | 625 kVA / 500 kW | 688 kVA / 550 kW |
| 800 kVA | 800 kVA / 640 kW | 880 kVA / 704 kW |
| 910 kVA | 910 kVA / 728 kW | 1000 kVA / 800 kW |
| Voltage | 230 / 400 V (three-phase, 4 conductors) | |
| Frequency / speed | 50 Hz / 1500 rpm | |
| Power factor | 0,8 | |
| Cooling / starting | Liquid / 24 V DC electric | |
| Configurations | Open, soundproof canopy, containerized | |
| Standard / marking | ISO 8528, CE marking | |
How to choose the right power
Sizing starts with the loads the generator must support: high-power motors, industrial refrigeration systems, pumps, continuous processes and critical equipment. Add their power requirements, then include a reserve for motor starting currents, which can briefly be several times higher than nominal current.
Do not oversize excessively: a generator operated for long periods at too little load does not work at its optimum point. Send us your load list and we will size the correct rating from the 450-910 kVA range and tell you whether a 625 kVA generator covers the requirement or whether the adjacent rating is more suitable.
Operating mode and autonomy
ISO 8528 defines prime power (PRP), available for an unlimited number of hours per year, and emergency standby power (ESP), available for a limited number of hours without overload. This line is rated for both, so it can operate either as the main source or as backup.
Autonomy depends on tank capacity and load. The integrated tank covers a typical standby duty, while extended operation can use a larger tank or external fuel supply. Diesel consumption at 75% and 100% load is stated in the datasheet for each rating.
Why diesel
For industrial power levels, the diesel engine remains the solution with the best balance of cost, autonomy and reliability. It offers high energy density, controlled fuel consumption under load and durability in intensive operation, unlike petrol generators, which are limited to lower power levels.
Unlike a UPS, which covers only a few minutes, a diesel generator can support the load for hours or days as long as fuel is available. That is why it is the standard backup choice for buildings, industry and critical infrastructure.
Components and construction
The technical platform is common across the entire line: liquid-cooled diesel engine, brushless alternator with 100% copper windings and automatic voltage regulator, digital controller with protections, and a frame with anti-vibration mounts for stable installation.
Components are selected for continuous operation and easy spare-parts support. A generator built on a unified platform is easier to maintain and troubleshoot, regardless of the selected power rating.
Configurations and options
Each 625 kVA generator is supplied in the configuration suited to its installation site: open for a technical room or hall, soundproof enclosed for low-noise outdoor installation, or containerized and ready to position, with external access to the control panel.
Options include an ATS automation panel for automatic mains-generator transfer, an extended fuel tank for greater autonomy, industrial sockets and a remote monitoring system. The three-phase output connects directly to the installation's main distribution board.
Applications and industries for the 625 kVA generator
A 625 kVA generator powers large factories, continuous-production halls, data centres and industrial sites. As a standby source it automatically takes over the entire facility during an outage; as a prime source it supports processes where grid capacity is insufficient or unstable.
In heavy industry, utilities and large logistics facilities, a high-power diesel generator supports large motors, pumps, refrigeration plants and conveyors. Soundproof enclosed or containerised versions allow fast, independent installation directly on the site.
For large hospitals and critical infrastructure, a 625 kVA generator is a core element of the continuity plan. See the full GENKRAFT diesel generator range for the rest of the range, or request sizing from the GENKRAFT technical team. All equipment carries CE marking in accordance with the applicable requirements of Machinery Directive 2006/42/EC.
Whatever the application, a 625 kVA generator delivers the same stable three-phase power, with optional automatic starting and a configuration selected for the installation site. A common technical platform across the 450-910 kVA range means shared parts and predictable service.
Installation, delivery and documentation
As a reseller, we prepare every order to the selected configuration: power, enclosure, voltage and options. Delivery time therefore depends on the configuration and is confirmed in the quotation together with the final price.
At delivery, the equipment comes with CE marking and conformity documentation. On request, we provide the technical datasheet and certifications required for a financing file. Electrical connection and commissioning are performed by an authorised electrician in accordance with the site's electrical design.
How it works
A 625 kVA generator follows a simple sequence from mains failure to restoration:
- The mains sensor detects loss of supply or a voltage deviation in the public grid.
- The ATS automation panel commands the diesel engine to start and disconnects the mains.
- The generator reaches rated speed and the alternator delivers stable three-phase voltage.
- Within a few seconds of the outage, the ATS transfers the load to the generator without human intervention.
- When mains power returns, the system transfers the loads back and stops the engine after the cool-down period.
- The digital controller monitors operating parameters and shuts the set down on protection events, with an alarm log.
Frequently asked questions
What is the difference between prime and standby power for a 625 kVA generator?
Prime power is the continuous rating available for an unlimited number of hours per year; standby is the emergency rating for a limited number of hours, without overload. The 625 kVA generator is rated for both according to ISO 8528, as shown on the datasheet for each power step.
What power range does the range cover?
From 450 to 910 kVA. The 625 kVA generator is a mid-range configuration; choose the rating that fits your factory or building.
Does it automatically take over the building during a power outage?
Yes. With an ATS panel, a high-power diesel generator starts and transfers the load within seconds, then automatically switches back to the grid. For critical buildings, we recommend ATS as standard.
What configurations are available?
Open for a technical room, soundproof enclosed for low-noise outdoor installation, or containerized. The 625 kVA generator is supplied in the version that best suits the site.
What maintenance does it require?
Basic maintenance means checking the oil, filters, coolant and battery at the intervals specified in the manual. The digital controller provides early alarm indications, and regular maintenance ensures a long service life.
Can it be monitored remotely?
Yes, optionally. With the monitoring module, generator status, fuel level and alarms can be viewed remotely over the network, which is useful for unattended sites.
How do I order and receive a quote?
Choose the power rating and configuration, then request a quote. We confirm the configuration, price and delivery time. Because each unit is prepared to order, you receive exactly the version suited to your project.
What is the noise level in the enclosed version?
The soundproof enclosure significantly reduces noise compared with the open version, allowing the generator to operate near the building. The exact dB(A) level at 7 metres is stated in the technical datasheet for each power rating.
Do you deliver nationwide?
Yes, we deliver throughout Romania. Electrical connection and commissioning are performed by an authorised electrician in accordance with the site's electrical design, and we provide the required technical documentation.
Is it eligible for projects funded by European funds?
Yes. The equipment comes with CE marking and conformity documentation, so it can be included in co-financed investment projects. On request, we provide the technical datasheet and certifications for the financing file.
Robust, three-phase and configurable across the 450-910 kVA range, a 625 kVA GENKRAFT generator takes over your factory or building without voltage dips, at direct-supplier pricing.
Complete specifications
| Power (kVA) | PRP kW | PRP kVA | ESP kW | ESP kVA | Voltage | Frequency | Tank (L) | Consumption (L/h) |
|---|---|---|---|---|---|---|---|---|
| 450 | 360 | 450 | 400 | 500 | 220/380V | 230/400V | 240/415V | 50 | 600 | 91.8 |
| 500 | 400 | 500 | 440 | 550 | 220/380V | 230/400V | 240/415V | 50 | 650 | 102.0 |
| 625 | 500 | 625 | 550 | 688 | 220/380V | 230/400V | 240/415V | 50 | 750 | 127.5 |
| 800 | 640 | 800 | 704 | 880 | 220/380V | 230/400V | 240/415V | 50 | 900 | 163.2 |
| 910 | 728 | 910 | 800 | 1000 | 220/380V | 230/400V | 240/415V | 50 | 1000 | 185.6 |