Genkraft
GENKRAFT / Diesel generators / DOOSAN GENKRAFT GK-D P1
Diesel generator set · 50 Hz

DOOSAN GENKRAFT GK-D P1
Diesel Prime & Standby

A single design family, same engine and alternator base, available across the entire power range.

Power range
150 – 400 kVA
· 7 steps
DOOSAN GENKRAFT GK-D P1 - Image 1
Configure

Choose power and execution

Configure the generator according to your needs. Choose the required power, execution type and desired options.

Specifications are automatically updated based on your selection

50 Hz
Prime Power (PRP)
150kVA / 120 kW
Standby Power (ESP)165 kVA
Rated current217 A
Technical sheet · marked values change with selection
Voltage / Frequency220/380V | 230/400V | 240/415V / 50 Hz
Dimensions (L×W×H)3050 × 1150 × 1780 mm
Operating mass2,130 kg
Fuel tank250 L
Consumption at 100% load30.6 L/h
ExecutionOpen

Prefer to talk? Call +40 769 081 081

Product description

275 kVA GENKRAFT diesel generator, three-phase 150-400 kVA

Do you operate a factory, large building or production facility and need a dependable standby source? A 275 kVA GENKRAFT generator belongs to a robust industrial range from 150 to 400 kVA, suitable for major loads and processes that cannot tolerate interruptions.

It is one configurable product across the full range: choose the power rating, enclosure and options. A 275 kVA generator delivers stable three-phase power at 400 V and 50 Hz, with prime and standby ratings, and can start automatically on grid failure to protect the entire building.

Advantages of a GENKRAFT industrial diesel generator

  • Configurable 150-400 kVA range: choose the right power level, from the smallest to the largest rating in the line, without paying for unused capacity.
  • Prime and standby ratings are stated in accordance with ISO 8528, so you know exactly what a 275 kVA generator delivers in each operating mode.
  • Stable three-phase supply at 230/400 V and 50 Hz, matching the Romanian grid standard and suitable for motors and sensitive equipment.
  • Automatic start on mains failure with an optional ATS panel, so a 275 kVA generator takes over the loads without human intervention.
  • Three configurations: open for a technical room, soundproof enclosed for outdoor installation, and containerized for a fully independent installation.
  • Liquid-cooled diesel engine and brushless alternator with 100% copper windings, components selected for reliable operation and dependable starting.
  • CE marking and conformity documentation, making the 275 kVA generator eligible for projects financed with European funds.
  • Direct-supplier pricing without the markup of an expensive brand: you pay for the technology and components, not the name on the enclosure.

Technical specifications for the 275 kVA generator and the rest of the line

A 275 kVA generator is part of a unified product line: the power rating changes while the platform remains the same. The values below are actual prime and standby ratings. Exact dimensions and weight are confirmed in the technical datasheet for each power step.

Model (kVA)Prime power PRPStandby power ESP
150 kVA150 kVA / 120 kW165 kVA / 132 kW
200 kVA200 kVA / 160 kW220 kVA / 176 kW
225 kVA225 kVA / 180 kW250 kVA / 200 kW
275 kVA275 kVA / 220 kW313 kVA / 250 kW
300 kVA300 kVA / 240 kW330 kVA / 264 kW
375 kVA375 kVA / 300 kW413 kVA / 330 kW
400 kVA400 kVA / 320 kW440 kVA / 352 kW
Voltage230 / 400 V (three-phase, 4 conductors)
Frequency / speed50 Hz / 1500 rpm
Power factor0,8
Cooling / startingLiquid / 24 V DC electric
ConfigurationsOpen, soundproof canopy, containerized
Standard / markingISO 8528, CE marking

How to choose the right power

Sizing starts with the loads the generator must support: process lines, motors, pumps, refrigeration systems, ventilation and IT equipment. Add their power requirements, then include a reserve for motor starting currents, which can briefly be several times higher than nominal current.

Do not oversize excessively: a generator operated for long periods at too little load does not work at its optimum point. Send us your load list and we will size the correct rating from the 150-400 kVA range and tell you whether a 275 kVA generator covers the requirement or whether the adjacent rating is more suitable.

Operating mode and autonomy

ISO 8528 defines prime power (PRP), available for an unlimited number of hours per year, and emergency standby power (ESP), available for a limited number of hours without overload. This line is rated for both, so it can operate either as the main source or as backup.

Autonomy depends on tank capacity and load. The integrated tank covers a typical standby duty, while extended operation can use a larger tank or external fuel supply. Diesel consumption at 75% and 100% load is stated in the datasheet for each rating.

Why diesel

For industrial power levels, the diesel engine remains the solution with the best balance of cost, autonomy and reliability. It offers high energy density, controlled fuel consumption under load and durability in intensive operation, unlike petrol generators, which are limited to lower power levels.

Unlike a UPS, which covers only a few minutes, a diesel generator can support the load for hours or days as long as fuel is available. That is why it is the standard backup choice for buildings, industry and critical infrastructure.

Components and construction

The technical platform is common across the entire line: liquid-cooled diesel engine, brushless alternator with 100% copper windings and automatic voltage regulator, digital controller with protections, and a frame with anti-vibration mounts for stable installation.

Components are selected for continuous operation and easy spare-parts support. A generator built on a unified platform is easier to maintain and troubleshoot, regardless of the selected power rating.

Configurations and options

Each 275 kVA generator is supplied in the configuration suited to its installation site: open for a technical room or hall, soundproof enclosed for low-noise outdoor installation, or containerized and ready to position, with external access to the control panel.

Options include an ATS automation panel for automatic mains-generator transfer, an extended fuel tank for greater autonomy, industrial sockets and a remote monitoring system. The three-phase output connects directly to the installation's main distribution board.

Applications and industries for the 275 kVA generator

A 275 kVA generator is used in factories, commercial buildings, hospitals and hotels as a standby source for the entire installation. When the grid fails, it automatically takes over critical loads, from lifts and ventilation to medical equipment and process lines, without a noticeable interruption.

In industry and large livestock farms, an industrial diesel generator supports continuous processes: production, refrigeration, ventilation and pumping. Three-phase power handles demanding motor starts, while the soundproof enclosed version reduces noise in staffed facilities.

For medium-sized data centres and 24/7 facilities, a 275 kVA generator becomes part of the continuity plan. See the full GENKRAFT diesel generator range for higher power ratings, or request sizing from the GENKRAFT technical team. The equipment carries CE marking in accordance with the applicable requirements of the Machinery Directive 2006/42/EC.

Whatever the application, a 275 kVA generator delivers the same stable three-phase power, with optional automatic starting and a configuration selected for the installation site. A common technical platform across the 150-400 kVA range means shared parts and predictable service.

Installation, delivery and documentation

As a reseller, we prepare every order to the selected configuration: power, enclosure, voltage and options. Delivery time therefore depends on the configuration and is confirmed in the quotation together with the final price.

At delivery, the equipment comes with CE marking and conformity documentation. On request, we provide the technical datasheet and certifications required for a financing file. Electrical connection and commissioning are performed by an authorised electrician in accordance with the site's electrical design.

How it works

A 275 kVA generator follows a simple sequence from mains failure to restoration:

  1. The mains sensor detects loss of supply or a voltage deviation in the public grid.
  2. The ATS automation panel commands the diesel engine to start and disconnects the mains.
  3. The generator reaches rated speed and the alternator delivers stable three-phase voltage.
  4. Within a few seconds of the outage, the ATS transfers the load to the generator without human intervention.
  5. When mains power returns, the system transfers the loads back and stops the engine after the cool-down period.
  6. The digital controller monitors operating parameters and shuts the set down on protection events, with an alarm log.

Frequently asked questions

What is the difference between prime and standby power for a 275 kVA generator?

Prime power is the continuous rating available for an unlimited number of hours per year; standby is the emergency rating for a limited number of hours, without overload. The 275 kVA generator is rated for both according to ISO 8528, as shown on the datasheet for each power step.

What power range does the range cover?

From 150 to 400 kVA. The 275 kVA generator is a mid-range configuration; choose the rating that fits your factory or building.

Does it automatically take over the building during a power outage?

Yes. With an ATS panel, an industrial diesel generator starts and transfers the load within seconds, then automatically switches back to the grid when power returns. For critical buildings, we recommend ATS as standard.

What configurations are available?

Open for a technical room, soundproof enclosed for low-noise outdoor installation, or containerized. The 275 kVA generator is supplied in the version that best suits the site.

What maintenance does it require?

Basic maintenance means checking the oil, filters, coolant and battery at the intervals specified in the manual. The digital controller provides early alarm indications, and regular maintenance ensures a long service life.

Can it be monitored remotely?

Yes, optionally. With the monitoring module, generator status, fuel level and alarms can be viewed remotely over the network, which is useful for unattended sites.

How do I order and receive a quote?

Choose the power rating and configuration, then request a quote. We confirm the configuration, price and delivery time. Because each unit is prepared to order, you receive exactly the version suited to your project.

What is the noise level in the enclosed version?

The soundproof enclosure significantly reduces noise compared with the open version, allowing the generator to operate near the building. The exact dB(A) level at 7 metres is stated in the technical datasheet for each power rating.

Do you deliver nationwide?

Yes, we deliver throughout Romania. Electrical connection and commissioning are performed by an authorised electrician in accordance with the site's electrical design, and we provide the required technical documentation.

Is it eligible for projects funded by European funds?

Yes. The equipment comes with CE marking and conformity documentation, so it can be included in co-financed investment projects. On request, we provide the technical datasheet and certifications for the financing file.

Robust, three-phase and configurable across the 150-400 kVA range, a 275 kVA GENKRAFT generator takes over your factory or building without voltage dips, at direct-supplier pricing.

Complete specifications

Power (kVA)PRP kWPRP kVAESP kWESP kVAVoltageFrequencyTank (L)Consumption (L/h)
150120150132165220/380V | 230/400V | 240/415V5025030.6
200160200176220220/380V | 230/400V | 240/415V5030040.8
225180225200250220/380V | 230/400V | 240/415V5035045.9
275220275250313220/380V | 230/400V | 240/415V5040056.1
300240300264330220/380V | 230/400V | 240/415V5045061.2
375300375330413220/380V | 230/400V | 240/415V5050076.5
400320400352440220/380V | 230/400V | 240/415V5055081.6